Subnet Solutions PowerSYSTEM Center
MODERATE ACTIVE Cyber · ics-advisory
VERIFIED Confirmed by the issuing agency or the affected provider itself.
- Source
- CISA — ICS advisories
- Geographic scope
- NATIONAL
- First seen
- Sun, Nov 22, 2026, 08:00 ET
- Last updated
- Tue, Nov 3, 2026, 07:00 ET
Reports
-
Subnet Solutions PowerSYSTEM Center
CISA — ICS advisories · published Tue, Nov 3, 2026, 07:00 ET · fetched Sun, Nov 22, 2026, 08:00 ET
Report text
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to execute unauthorized SQL commands and gain access to unauthorized resources. The following versions of Subnet Solutions PowerSYSTEM Center are affected: • PowerSYSTEM Center 2020 <=5.29.x (CVE-2026-63017) • PowerSYSTEM Center 2024 >=6.0.x|<=6.2.x (CVE-2026-63017, CVE-2026-63774) • PowerSYSTEM Center 2026 >=7.0.x|<=7.1.x (CVE-2026-63017, CVE-2026-63774) CVSS Vendor Equipment v3 9 Subnet Solutions PowerSYSTEM Center 2 Vulnerabilities Incorrect Authorization, Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') Background • Critical Infrastructure Sectors: Critical Manufacturing, Energy • Countries/Areas Deployed: Worldwide • Company Headquarters Location: Canada Vulnerabilities Expand All + CVE-2026-63017 Incorrect authorization in PowerSYSTEM Center allows a low-privileged, authenticated user to access resources normally limited to administrators. Read More 3 Affected Products Subnet Solutions PowerSYSTEM Center 2024 >=6.0.x|<=6.2.x Product Status: known_affected Remediations Mitigation For users who are currently using PowerSYSTEM Center 2024, Subnet Solutions recommends users upgrade to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com. If unable to update to the latest version, Subnet Solutions recommends users monitor user activity records to ensure users are following acceptable usage policies of the application. Subnet Solutions also recommends disabling PowerSYSTEM Center Client Access Server users' ability to access the browser's F12 Developer Tools. Subnet Solutions PowerSYSTEM Center 2020 <=5.29.x Product Status: known_affected Remediations Mitigation Subnet Solutions recommends users update to PowerSYSTEM Center 2020 Update 30. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com. If unable to update to the latest version, Subnet Solutions recommends users monitor user activity records to ensure users are following acceptable usage policies of the application. Subnet Solutions also recommends disabling PowerSYSTEM Center Client Access Server users' ability to access the browser's F12 Developer Tools. Subnet Solutions PowerSYSTEM Center 2026 >=7.0.x|<=7.1.x Product Status: known_affected Remediations Mitigation Subnet Solutions recommends users update to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com. If unable to update to the latest version, Subnet Solutions recommends users monitor user activity records to ensure users are following acceptable usage policies of the application. Subnet Solutions also recommends disabling PowerSYSTEM Center Client Access Server users' ability to access the browser's F12 Developer Tools. Additional Metrics Relevant CWE: CWE-863 Incorrect Authorization CVSS Version Base Score Base Severity Vector String 3.1 9 CRITICAL CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H 4.0 9.4 CRITICAL CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H View CVE Details CVE-2026-63774 Insufficient input validation in the PowerSYSTEM Center report designer allows an authenticated user to execute unauthorized SQL commands. Subnet Solutions PowerSYSTEM Center 2024 >=6.0.x|<=6.2.x Product Status: known_affected Remediations Mitigation For users who are currently using PowerSYSTEM Center 2024, Subnet Solutions recommends users upgrade to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8…
Timeline
- CREATED by system — status: ACTIVE; severity: MODERATE; externalId: ICSA-26-307-01
Relations
No relations.